Second degree AV Block type II (aka Mobitz II)
 • ...
1.5K
Description

Second degree AV Block type II (aka Mobitz II)

 • There is constant PR interval (normal or prolonged) before a P wave is dropped.

 • The QRS is usually widened because the location of the block is often infranodal.

 • The QRS complex maybe narrow indicating a more proximal location of the block (AV node).



#Second #Degree #AVBlock #TypeII #MobitzII #Type2 #diagnosis #cardiology #ecg #ekg #electrocardiogram #Mobitz2
Contributed by

Dr. Arnel Carmona
@ecgrhythms
Internal Medicine (IMG) , lover of the squiggly lines and all simplistic learning

https://twitter.com/ecgrhythms - blogger @ - https://www.ekgrhythm.com/